TF-600D/600V
Description:
The TF-600D/600V series mass flowmeter has evolved from the existing cost-effective TF-600 mini thermal mass flowmeter; and features an easy-to-read digital indicator and analog or digital (optional) signal output function. Indication can be either checked at the site or remotely managed. The lineup includes a model with a flow adjustment valve, which is ideal for being mounted on units for saving space。
Download file
| Model | TF-600D/600V | |
| Fluid | Air, N2 | |
| Function | Local indication Voltage output Pulse output Alarm output RS-485 |
|
| Measuring range (air) |
Min | 0 ~ 5 L/min(nor) |
| Max | 0 ~ 8000 L/min(nor) | |
| Process connection | Rc 1/4 ~ Rc 1-1/2 | |
| Standard material | SCS14,SUS316 | |
| Accuracy | ±3% F.S. | |